When a clinic or healthcare facility starts making use of Presbyopic Intra-ocular lenses (IOLs), a frequently asked question is: what features should we take into consideration when choosing patients for presbyopia-correcting IOLs?
Also before choosing the appropriate IOL as well as target refraction, the most crucial element to successful cataract surgery is getting to know the person’s personality as well as visual goals:

Personality & Vision Objectives

– It is well established and also extensively acknowledged that the primary criterion for picking a suitable multifocal patient is his/her willingness to be rid of eyeglasses. If your patient does not request independence from glasses and does incline wearing them, this patient is not appropriate for this type of IOL implant. Refractive patients are most likely to see the photic side effects of multifocal IOLs than regular cataract patients. Patients that have actually had previous refractive surgical procedures frequently reveal additional loss of contrast with a decrease in visual quality.
– The individual’s characteristics and also his/her personality are elements to take into consideration. For instance, an individual who is very vital and has extremely high expectations offered a source of concern. Positive, easy-going individuals that comprehend that an operation involves risks as well as agree to approve compromises on visual acuity for freedom from eyeglasses are the perfect prospects.
– Take the person’s way of life into consideration. Are glasses causing hassle during activities? As an example, when swimming, golfing, or switching from reading glasses to no glasses during meetings or presentations. And how essential is the visual quality in low light conditions to your patient? There are occupations that make multi-focals unadvisable – pilots, drivers, and astronomers as well as anybody whose job needs working at night or in low-light conditions.

Next off, you can help patients to choose the most effective lens model for them, with recommendations based on your pre-op measurements and also experience. So, what corneal and eye measurements should be done? Nowadays, there are numerous different types of tools that can assist attain precise pre-operative diagnostics.

Pre-op measurements

Which diagnostics should be executed? These days there are numerous sorts of devices that help us to attain exact pre-operative diagnostics.
– Dry-eye and also meibomian gland disorder need to be treated pre-operatively.
If existing, analyze if the dry eye may be impacting the topography. If there is effect, deal with the dry eye pre-op as well as take a new measurement afterwards. If there is no influence on the topography, you can educate the patient of the dry eye as well as begin the treatment.
– Refractive errors after multi-focal intra-ocular lens (MIOL) implantation are a significant source of retreatment.
In terms of biometry, optical measurements of axial length are generally precise and much better than ultrasound. Make sure excellent K reading of the patient’s eye. Think about fourth generation formulas for the computation of the dioptric power.
– Evaluate the cornea; see to it that the person does not have a significant corneal cylinder (> 1.0 D), depending upon the steep axis. The visual acuity at whatsoever distances lowers in proportion to the diopters of astigmatism.
– It is very important to examine 3rd as well as fourth order corneal aberrations such as coma also. Anterior corneal coma values greater than 0.32 μm might cause intolerable dysphotopsia in the presence of a diffractive optics multifocal IOL.
– Validating the normal performance of the macula and also its anatomy is important. A test with an optical coherence tomographer (OCT) is advised.
– Other vital aspects that may affect the last outcome are angle kappa and pupil size. Centration of the MIOL is essential to accomplishing optimum optical efficiency. Patients with decentred implants might experience glare, halos and a decline of visual acuity. Angle kappa is the distance in between the pupil centre as well as the visual axis. When the optics of the implant as well as the optics of the eye align, great outcomes as well as delighted patients are far more likely. A lens can be perfectly centred within the pupil, yet the visual axis may not be precisely in the centre of the pupil. The pre-surgical reading of angle kappa helps to identify people that may not be optimal prospects for a MIOL.

– Patients with large pupils will be more likely to deal with glare. The pupil dimension should not exceed the IOL body diameter of 6.0 mm.
– Finally, eliminate ocular diseases that may predispose future difficulties (e.g. anterior segment pathology, glaucoma, corneal dystrophy, ocular inflammation, pseudo-exfoliation syndrome, retinal conditions).

Counselling patients
There is no finest way to counsel patients. Social and business distinctions have a huge effect on selecting the best approach.